Welcome to Anagrammer Crossword Genius! Keep reading below to see if rechose is an answer to any crossword puzzle or word game (Scrabble, Words With Friends etc). Scroll down to see all the info we have compiled on rechose.
rechose
Searching in Crosswords ...
The answer RECHOSE has 2 possible clue(s) in existing crosswords.
Searching in Word Games ...
The word RECHOSE is VALID in some board games. Check RECHOSE in word games in Scrabble, Words With Friends, see scores, anagrams etc.
Searching in Dictionaries ...
Definitions of rechose in various dictionaries:
verb - to take by preference
Word Research / Anagrams and more ...
Keep reading for additional results and analysis below.
Possible Crossword Clues |
---|
Picked anew |
Went for something else |
Last Seen in these Crosswords & Puzzles |
---|
Jun 1 2012 New York Times |
May 25 2006 New York Times |
Possible Dictionary Clues |
---|
Simple past of rechoose. |
Rechose might refer to |
---|
In electric power distribution, Automatic Circuit Reclosers (ACRs) are a class of switchgear which is designed for use on overhead electricity distribution networks to detect and interrupt momentary faults. Also known as Reclosers or Autoreclosers, ACRs are essentially High Voltage rated Circuit Breakers with integrated current and voltage sensors and a protection relay, optimized for use as an overhead network distribution protection asset. Commercial ACR's are governed by the ANSI/IEEE C37.60, IEC 62271-111 and IEC 62271-200 standards. The three major classes of operating voltage are 15.5kV, 27kV and 38kV. * For overhead distribution networks, the majority of faults are transient, such as lightning strike, surges or foreign objects coming into contact with the exposed distribution lines. By this logic, 80% of outages can be resolved by a simple close operation. . Reclosers are designed to handle a short close-open duty cycle, where electrical engineers can optionally configure the number of attempted close operations prior to transitioning to a lockout stage. Invented in the mid 1900s in the USA, reclosers were originally oil filled hydraulic devices with rudimentary mechanical protection relaying capabilities. Modern Automatic Circuit Reclosers are significantly more advanced than the original hydraulic units. The advent of semiconductor based electronic protective relays in the 1980s resulted in increased sophistication, allowing for differing responses to the various cases of abnormal operation or fault on a distribution networks. The high voltage insulation and interrupting device in modern reclosers typically consist of Solid Dielectric Insulation with vacuum interrupters for current interruption and arc quenching. Reclosers are often used as a key component in a smart grid, as they are effectively computer controlled switchgear which can be remotely operated and interrogated using SCADA or other communications. This capability allows utilities to aggregate data about their network performance, and develop automation schemes for power restoration. This automation can either be distributed (executed at the remote recloser level) or centralized (close and open commands issued by a central control room to be executed by remotely controlled ACRs).* |